Model
Qnom/Qmax*
Qnom
[dm3/s]
(NS)
Qmax
[dm3/s]
Dw
[mm]
Hw
[mm]
Amin**
[mm]
Diameter of inlet/outlet pipes DN
[mm]
Actual capacity of sedimentary section [dm3]Oil storage volume
[dm3]
Total weight
[kg]
Weight of the heaviest element
[kg]
ESL-Z 1,5/151,51512001220830max 40018015037002900
ESL-Z 3/3033012001220830max 40018015037002900
ESL-Z 6/6066012001220830max 40018015037002900
ESL-Z 10/1001010012001220830max 40018015037002900
ESL-Z 15/15015150120015301020max 60018030044003600
ESL-Z 20/20020200120015301020max 60018030044003600
ESL-Z 30/30030300150016001250max 80030075066005600
ESL-Z 40/40040400150016001250max 80030075066005600
ESL-Z 50/50050500150016001250max 80030075066005600
ESL-Z 60/60060600200015101310max 800550120093007600
ESL-Z 65/65065650200015101310max 800550120093007600
ESL-Z 70/70070700200015101310max 800550120093007600
ESL-Z 75/75075750200015101310max 800550120093007600
ESL-Z 80/80080800200015101310max 800550120093007600
ESL-Z 90/900 S90900250016201700max 12007901950143006700
ESL-Z 100/1000 S1001000250016201700max 12007901950143006700
ESL-Z 110/1100 S1101100250016201700max 12007901950143006700
ESL-Z 120/1200 S1201200250016201700max 12007901950143006700
ESL-Z 125/1250 S1251250250016201700max 12007901950143006700
ESL-Z 130/1300 S1301300250016201700max 12007901950143006700
ESL-Z 140/1400 S1401400300016301720max 120010702400189007200
ESL-Z 150/1500 S1501500300016301720max 120010702400189007200
ESL-Z 160/1600 S1601600300016301720max 120010702400189007200
ESL-Z 170/1700 S1701700300018101790max 120010703150172007500
ESL-Z 180/1800 S1801800300018101790max 120010703150172007500
ESL-Z 190/1900 S1901900300018101790max 120010703150172007500
ESL-Z 200/2000 S2002000300018101790max 120010703150172007500
ESL-Z 210/2100 S2102100300018101790max 120010703150172007500

 

*) Qnom [dm3/s] (NS) -nominal flow value for which > 99% impurities is stopped (value obtained during the tests according to norm EN 858-1).

Qmax [dm3/s] – maximum hydraulic flow capacity of the device, at which there is no danger of flushing out accumulated dirt.

**) Inreasing the A value through the use of additional superstructure rings.

S – devices delivered to the construction site in the elements.

Ecol-Unicon Company reserves the right to implement changes in equipment design without prior notice.